Devices
X ray / DR
An imaging diagnostic system designed to align with veterinary clinical workflows, delivering high-quality images for greater examination efficiency while its built-in generator maximizes space utilization.

Core Values
An all-in-one imaging diagnostic solution optimized for animal hospitals
Code-level mapping with IntoVet GE for real-time integration

Delivers consistent and high-quality images through optimized image processing

Compact design enables efficient operation even in limited clinical spaces

Key Features
Hardware Convenience
4-Way table: omnidirectional top movement (front/back/left/right) for maximum imaging flexibility
Touch interface: intuitive touchscreen with user-friendly GUI

Veterinary Console S/W
UI/UX optimized for workflow efficiency with dedicated image processing built in

High-Performance Technology
500mA high-frequency type for high-quality images even at low radiation doses

Intelligent Imaging System
Automatic kV/mA adjustment by imaging region
Veterinary body part graphics
Embedded software for parameter adjustment buttons

Key Features
Retro-fit DR Upgrade
A solution that easily converts (upgrades) existing analog equipment to digital
Quick Preview
Image preview within 3 seconds after capture, full image acquisition within 5 seconds
Auto Detection (AED) Mode
Automatically detects X-ray exposure for capture without separate wiring
Integrated Workflow
Patient order reception → imaging → PACS transmission and result verification in one flow
Product Specifications
| Category | DR Upgrade (Detector) | X-Ray System (Generator) |
|---|---|---|
| Model | 1717 Wired / Wireless (Csl) | VXR-E20 ~ E40 Series |
| Key Specs | 16 bit AD conversion / 139μm pixel pitch | Supports 20kW to 40kW output |
| Features | Supports high resolution (3.6 lp/mm) and IPX-rated waterproofing | 200-240V single-phase power, high-precision kV/mA control |
| Size | 17×17 inch (Supports large areas) | Compact design & 4-way table integrated |
| 1717 WIRED(Csl) | 1717 WIRELESS(Csl) | |
|---|---|---|
| Detector technology | Amorphous Silicon | - |
| Scintillator | Csl | - |
| Active area | 427 x 427 mm | - |
| Pixel matrix | 3072 x 3072 | - |
| Pixel pitch | 139μm | - |
| Spatial resolution | 3.6Ip/mm | - |
| AD conversion | 16 bit | - |
| Trigger mode | AED / Software / Prep | AED / Software |
| Full image time | 5 sec | - |
| Preview Image time | 3 sec | 4sec |
| Data interface | GlgE | 2.4G and 5G IEEE802.11 a/b/g/n/ac |
| Battery operation time | n/a | 5 h |
| Power consumption | 30 w | 16 w |
| Dimension | 460 x 460 x 15 mm | - |
| Weight | 4kg | 4.6kg |
| Operating temperature | 5~35 ℃ | - |
| Operating humidity(% RH) | 30~80 % RH(Non-condensing) | 10~90 % RH(Non-condensing) |
| Strorage temperature(℃) | -10~55℃ | -20~55℃ |
| Storage Humidity(% RH) | 10~90 % RH(Non-Condensing) | 5~95 % RH (Non-Condensing) |
| Application | Medical / VET | - |
* Upgrade and Options : Cable, Power unit, Battery charger
| Generator Model | VXR-E20/EC20 | VXR-E25/EC25 | VXR-E32/EC32 | VXR-E40/EC40 |
|---|---|---|---|---|
| Output Rating | 20kw | 25kw | 32kw | 40kw |
| Line Power Rating | 200V-240V, 1Φ, ±10% (50/60Hz) / 100-120V, 200V-240V, 1Φ, ±10% (50/60Hz) | |||
| Reproducibility | Coefficient of Variation: kV < 0.005, Time < 0.005, mAs < 0.01, mR < 0.01 | |||
| Accuracy | kV < ±(1%+1kV), mA < ±(3%+1mA), Time < ±(1%+0.5ms), mAs < ±(3%+0.1mAs) | |||
| Linearity | Coefficient of Linearity < 0.01 : CL = (X1-X2)/(X1+X2), where X is mR/mAs | |||
| Detector Model | MANO4336W | MANO4343W | MANO4343T |
|---|---|---|---|
| Fixed/Wireless | Wireless | Wireless | Fixed |
| Size | 14x17 | 17x17 | 17x17 |
| Scintillator | Csl | ||